Versie historie van TS-Doctor
<<Terug naar software beschrijving
Veranderingen voor v1.2.165 - v1.2.166
- Volume in the cutting windows was not changable
Veranderingen voor v1.2.154 - v1.2.161
- Undo function in the cutting window (CTRL + Z)
- Enigma-AP/SC-indexer processed also TS files that were created with Videoredo
- Hotkey function of the delete key is now switched off when changing to the file separation dialog
- Workaround for "Previous I-frame" in the timeline panel when using LAVFilters
- Fixed problem with sporadic not working "Previous I-frame" when using Haali-Splitter
- Fixed bug in the SampleGrabber which could lead to hang of the playback graph in certain configurations
- Enigma AP/SC indexer improved
- Removing marked section via the delete key, if a marker is enabled in the cutting window
- Removing cutting areas via the delete key, if no marker is enabled in the cutting window
- Fallback for cutting images, when problems with fast Samplegrabbing
- Inaccuracies cutting images with the help of the fast SampleGrabbings in the cutting window
- "AAC small PTS delta"- problem fixed in TS Remuxer logfile
- Double rows of Teletext subtitles (Polish HBO) will be merged now
- Increased buffer for EmulationPrevetions (ORF Sport + HD)
- Fallback if Teletext time format has changed
- Adjusted changed Teletext time format for ARD-Alpha
Veranderingen voor v1.2.148 - v1.2.154
- Filters out of PID 17 (SDT,BAT,ST) during playback in the cutting window, otherwise HaaliSplitter hangs
- Insert of AC3 silence in TS Remuxer updated
- When Teletext X26 characters used the color attributes are respected
- Support for FreeSat(UK) EPG compression
- Missing or only partially existing stream resulted in a long delay when creating a new file
- Adjustment for changed Teletext of SIXX
- Fixed problems with the date format for DVBViewer EPG data
- Problems with French teletext subtitles on Arte channel fixed
- Catching fails to connect the audio components in the cutting window (under MacOS/Wine)
- Entry for English-based (other) in ISO639 list moved to the correct position
- Priority changed while selecting character set in the Teletext improved (especially for Russian television)
- Fixed flickering of progress bar when skin is disabled
Veranderingen voor v1.2.147 - v1.2.148
- Support for Teletext with cyrillic and greek character sets
- Improved detection of 192 byte TS packets
- Shows MPEG audio details
Veranderingen voor v1.2.144 - v1.2.147
- Problem with download of additional tools under Linux fixed
- "Default Language Descriptor" was ignored for recreated PMTs
- No unwanted file separation while automatically remove encrypted areas
- tsMuxeR not correctly detected during installation
- Support for ADS info from the "DVB recording service"
- After the repair of a timer jump or removing encrypted areas the programme guide was no longer fully scanned
- Improved Teletext TV Guide
- Support for taking over Fortis FTRI packets, so that the recordings remain playable on Fortis receivers
- Faster CRC32 check (8x faster routine)
Veranderingen voor v1.2.143 - v1.2.144
- Fixed a restart problem of the trial version
- Download option of additional tools during Setup
- Commandline parameter for the target directory now also works for single files
Veranderingen voor v1.2.142 - v1.2.143
- Improved Teletext processing
- Additional channels included in the Teletext processing
- Fixed problems with SIXX-Teletext
- Disabled audio tracks and subtitles have been incorrectly applied to the batch list
Veranderingen voor v1.2.141 - v1.2.142
- Hotfix for problems with the file dialogs (program termination without error message)
- In radio mode the LAVSplitter is prefered, because the Haali splitter produces no audio for recordings without video stream
- Support for recording of TechniSat ISIO S receivers
- File Merger now supports the merging of overlapping recordings
- Incomplete audio streams will now be ignored in preview to circumvent problems with Haali Splitter
Veranderingen voor v1.2.134 - v1.2.141
- Teletext TV guide for German Sky channels improved
- EIT can be ignored via advanced options in the file open dialog
- Various graphic elements made independent of the skin engine
- Fixed error message "No mapping for Unicode characters in the multibyte target code page exists" when opening older recordings
- Fixed incorrect duration displayed for recordings with PCR-wrap
- Teletext processing improved for swiss channels
- Fixed problems with certain special characters for teletext channels in Czech
- Adopted various Czech stations for teletext analysis
- VPS auto cutting for Czech TV channels CT1, CT2 and Nova
- Flickering in progress window fixed, if skin is disabled
- Installation scripts completely rewritten
- More detailed search for teletext subtitles
- Problems fixed in TS Remuxer and TS Demuxer for ATSC recordings, where audio and video PIDs are below 32
- Fix for Trial under VM and Wine
- Show title recognition via Teletext improved (NDR problem)
- Possibility to enter compatible filters by registry entry
- Support for PowerDVD 14 video filters
- Skin surface made can be switched off (for wine/crossover - compatibility)
- Timeline now accessable even without skin engine
- Skin surface under wine/crossover switched off by default, to prevent hangin in the cutting window
- Time values now correctly for created SRT subtitles, even if Teletext PTS is missing or incorrect
- Compiler update
- Update of skin engine
- New trial time
- Choice for H265 video filter in the settings
- For H265 recordings the LAV splitter is selected, because Haali splitter does not support H265
- Trial of the TS doctors under VM possible but with 500MB-Limit for the output file
- Detection of H265/HEVC video streams
- Detection of DolbyE video streams
- H265/HEVC cutting (PES)
Veranderingen voor v1.2.133 - v1.2.134
- Hotfix for not fully activated preview when using the Microsoft audio filter under Windows 7
- - When inverting the cut list the cutting images are now updated accordingly
Veranderingen voor v1.2.128 - v1.2.133
- I-frame detection is working now for LAVSplitters too
- More improvements for American cable TV
- Evaluation of all EPG data in ATSC recordings
- Improved adaptation of the aspect ratio of screen shots in the cutting window
- Fixed problem with manual detection of advertising in multi-part recordings
- Detection of EIA-608 data in MPEG2 streams
- Use of P-frames for the CutOuts in H264 can be turned off to avoid video artifacts
- Play button only active after creating the cutting images
- Improved handling of recordings from the United States (ATSC)
- Improved recognition of ATSC recordings
- Evaluation of the VirtualChannelTable and the SystemTimeTable for ATSC recordings
- Anamorphic adaptation of screenshots in the timeline panel
- Fixed potential deadlock in H264 processing
- Screenshot in cutting window via shortcut "[Alt] i"
- Teletext analysis for Italian channels added (Rai1,Rai2,Rai3,Canale5,Italia1,TGCom24)
- Better detection of the recording start via Teletext even for unknown channels
- Detection of recordings of Dutch TV stations NED1, NED2 and NED3 via cable
- Sporadic problems with Kathrein UFS912 recordings fixed
- Working progress in garbage scan
- File position error for recordings with less than 10% usable data fixed
- More than 20% fill data (garbage at the beginning and end), garbage-scan box remains yellow as a warning
- Detection of private streams like Kronehits
- PES demuxing of private streams
- The CRC of newly created files will be found in the log now
- The CRC of any files can now be calculated in the menu under Tools
Veranderingen voor v1.2.125 - v1.2.128
- Display of the station name for recordings of an entire transponder with all PIDs
- No longer functioning SRT Time Changer fixed
- Better support for transponder recordings with many encrypted stream
- Now also PCR jumps at the end of recordings are detected correctly
- Very short cutting areas (less than 500ms) are filtered for the automatic cut to avoid cutting problems
- Evaluation of the Service_Descriptor_Table if found, to get the channel name
- Interpolation of the recording start time if no time information via Teletext or TOT is present
- If a file needs to be repaired first all streams remain in the fixed file
- Screenshot available even during playback in the cutting window now, playback is temporarily paused
- In the cutting window the cursor no longer moves to the end, when jumping backwards via -1m, -10s or -1s button
- Better support for splitted files of Kathrein UFS 903
- Fixed drag&drop of multiple files on the main window
- Support for channel logos (channelname.png)
- Uses automatically existing channel logos of DVBViewer
- VDR channel logo pack from 3PO can be downloaded
- Extracting recording infos from TechniSat REC files
- Teletext analysis improved for some channels and some channels added
- Year indication in the teletext analysis improved
Veranderingen voor v1.2.124 - v1.2.125
- Fixed problems with sporadic inexact first cutting point (since Beta 1.2.120)
Veranderingen voor v1.2.123 - v1.2.124
- Hotfix for version info of TSMuxer 2.0.8(b)
Veranderingen voor v1.2.116 - v1.2.123
- DVD-Maker problem for recordings with a & in the file name fixed
- In the cutting form a jump will lead to an update of the selected cutting area
- Fixed problem that the first I-frame was not considered for the initial cut
- Better consideration of the PCR/PTS delay in determining the cutting point
- Code optimization for faster program start
- Own and faster detection routine of the DirectX version on DLL version instead of DXDiag
- Drag&Drop of files updated
- Ignore transport_scrambling_control for detection of the stream start
- Lesebuffer optimized for analysis
- Raw cutter updated
- Automatic stream selection for subtitles and audio streams based on language and format
- New version control for "supported tools"
- Teletext utilization for several Belgian channels added
- "Devision by zero" bug for radio recordings fixed
- Removing areas while creating cutting point images blocked
- Removal of incomplete shows is performed for commercials detection via the menu, too
- Potential problems while removing areas at the end of a recording fixed
Veranderingen voor v1.2.114 - v1.2.116
- 1.2.116
- Fix for problems with thumbnails and single frame view
- 1.2.115
- Fixed problem with delayed subtitles of Finnish channels
- Current selected section is now adjusted according to the cut
- Improved support for multiple concurrent instances of the TS-Doctor
- TS-Doctor renderer optimized and support for YUY2 format and VideoInfoHeader2
- No more illegal timer jump detected for ordinary PCR wraps
- Problem "no audio data written" for recordings with PCR wrap fixed
- Updated Teletext TV guide for SWR channel because of changes
Veranderingen voor v1.2.108 - v1.2.114
- Improved detection and removal of PCR jumps on BBC channels
- Improved automatic removal of encrypted areas
- Fixed sporadic wrong detection of PCR drift for recordings of BBC channels
- Download of tools and updates changed to WinINet API
- Checking for Internet connection before attempting to download something
- Windows XP x64 was incorrectly compatibility mode detected even though this was not active
- Support for downloading tools and updates via SSL
- Improved installation of tools
- Support for version 0.61.0 of LAVFilters
- Repair of recordings where the PCR value drifts (Haupauge HD PVR2 problem)
- Revised overwrite warning for saving of cutting lists
- TV guide via teletext for Pro7 FUN, ProSieben MAXX, VIVA Germany, Disney Channel
- Error message for files with file size zero
Data from the xml file of neutrino recordings is inserted in the description - Improved extraction of movie infos from the teletext
- Broadcast standard was disregarded in some cases for ATSC recordings
- Fixed several potential problems with the editing of recordings with PCR-wrap
- Warning shots, where the PCR value drifts
- Compatible to Haali-Splitter from K-Lite Codec Pack
- Problem with volume setting in error preview window fixed
- Sporadic problem fixed "no audio data is written" for recordings with PCR-wrap
- Fixed a problem with the close button in the dialogs
- Support for the new tsMuxeR version 2.6.11 including tsMuxerGUI
- Support for current versions of ComSkip (free & donator)
- If a recording has to be repaired first, teletext and subtitles are no longer removed unintentionally
- Overwrite warning for saving of cutting lists
- Fixed a potential problem with UTC time correction in the EPG TV Guide
Veranderingen voor v1.2.104 - v1.2.108
- If bad EPG data is detected, the EPG will be ignored (occurred more frequently at ORF)
- Bad EPG data no longer lead to hang the EPG-evaluation
- Visualized creation of the EPG TV guide
- Improved resolution of TV guide
- Advanced options on opening a file (force new PAT/PMT)
- If incorrect EPG found the TV guide is generated via teletext
- Maximized State of the cutting window is stored now in addition to the screen position
- Sporadic problems for very short TechniSat recordings fixed (less than 100 MB)
- Warning when attempting to run the TS-Doctor in Windows compatibility mode, as this can cause problems
- Improved support of Swiss television channels SRF 1, SRF zwei, SRF info, RSI LA 1, RSI LA 2
- Improved automatic cutting for SRF 1, SRF zwei, SRF info, RSI LA 1, RSI LA 2
- Automatic detect and remove commercials for SRF 1, SRF zwei, SRF info, RSI LA 1, RSI LA 2 in EPG/VPS cutting mode (as far as possible)
- Fixed various issues with the EPG cutting
- Incorrect EPG status no longer hang the application
- "Fix incorrect TechniSat cuts" in the settings fixed
- Audio errors were shown only if file was cutted
- Fix for sporadic still wrong film details after working with Sky recordings
- Default file name for screenshot (recording file name + [time])
- Fixed a bug when detecting the sound format of ORF3
- Sporadic problems with cleaning of the song titles for "Deluxe Music" and EPG cutting fixed
- VPS cutting was offered for ZDFinfo although the Teletext does not belong to ZDFinfo
- Fixed issue with the internal TV Guide for sky recordings, when the recording occurred shortly after midnight
- Fixed a bug in the single frame display
- Sporadic wrong film details in additional file of Sky recordings
Veranderingen voor v1.2.100 - v1.2.104
- Sporadic error fixed "No audio data has been written"
- Improved handling of music recordings
- Automatic removal of advertising blocks for "Deluxe Music" via EPG-cut
- Automatic cleaning of song titles for recordings from "Deluxe music" with EPG-cut
- Timeline is drawn much faster
- Significantly reduces CPU load in the preview window
- Packages without payload are no longer listed in the log but as the sum at the end of the log
- Fixed sporadic signed bug when removing the PCR jumps
- Fixed sporadic faulty PCR display in the progress window
- AC3 format changes were shown in the log even though they were outside of the cutting areas
- Fixed sporadic hanger for audio format change (BBC THREE)
- Fixed a bug in the Skinengine
- Brazilian ISDB-TB standard can be selected as broadcast standard
- Wrong PMT entries for certain audio tracks can be fixed (Brazilian TV)
- Fixing of problematic TechniSat cuts can be deactivated in the settings
- For some Danish channels, the AAC track was not recognized
- Revised detection of audio formats for improved detection of MPEG1 audio
Veranderingen voor v1.2.96 - v1.2.100
- Improved AAC parser
- On saving a file, spaces are removed from the beginning and end of the file name
- Fix for install in another directory as the default directory
- The I-frame detection is enabled by default on the wine/crossover
- Support for ATI MPEG2 Decoder Filter
- Support for AMD Video Decoder Filter (MPEG2)
- For setting "AUTOMATIC" the "enhanced video renderer" is now used in Windows Vista/7/8 as "Default Video Renderer"
- Workaround for sporadic missing audio in the timeline when you use the Microsoft DTV-DVD audio decoder
- Color information of Teletext subtitles can be applied in the SRT export
- Wine/Crossover compatible video renderer
- Improved search for time jumps within the recording
- Fixed a potential problem at startup (14%)
- After repair of recordings with time jumps, opening of the repaired recording is offered now
- PMT problem with processing of VLC recordings fixed
Veranderingen voor v1.2.95 - v1.2.96
- Fix for automatic update of trial versions
Veranderingen voor v1.2.90 - v1.2.95
- Trial reset, new version can be tested 30 days again
- Installation in multi user enviroment improved
- Improved error handling during automatic update and tool installation
- Fixed a potential problem with the re-creation of a PMT for defective or missing PMT
- Improves troubleshooting of TechniSat recordings with timer problems, because by cut function in the receiver
- Improved Teletext programme guide
- Support of Dutch Teletext(Nos) (NED1, NED2, NED3) for program overview
- Selection of the correct PMT improved, if there are multiple PMTs
- Working with the TS Haupauge HD PVR recordings, finally
- Identify and correct timing errors for TechniSat recordings that were cut with the receiver
- Memory usage of the application is displayed in the log
- ATSC to DVB conversion improved for AC-3 entries in the PMT
- If the cut list was inverted, the cuts were not saved correctly for the reopening
- FAT/FAT32 file system warning for files that are larger than 4 GB, can be disabled in the preferences
- The scrambled flag will be ignored by default and no dialog box opens
- Sporadic errors in the result dialog fixed
- New display of error distribution in the result dialog
- Improved recognition of stream types by searching at 3 different stream positions
- Improved recognition of regional programme switching
- French program translation improved (Thanks Phil)
Veranderingen voor v1.2.89 - v1.2.90
- Fixed display of the cut list if cutting images are disabled
- Option to turn off parity-check on Teletext subtitles (necessary for British channels "Watch.")
- Double click was necessary in the cut list to jump to the beginning or end of a cutting range
- Teletext program overviews for German Sky channels improved
- In the timeline panel, the playback speed is no longer changed when jumping in the timeline
- Fixed bug in patching the AC3 tracks in the PMT
Veranderingen voor v1.2.87 - v1.2.89
- Automatic update respects now the previously chosen installation folder
- First entry in the Batchliste was displayed incorrectly
- Design of the cutting list improved
Veranderingen voor v1.2.82 - v1.2.87
- Support for R5000-HD DVR recordings
- Processing of recordings where a non-DVB compliant stream type is used for MPEG2 in the PMT (Canadian satellite Anik F1)
- Detection and display of encrypted channels for transponder recordings
- Taking into account padding data in stream type detection (French DVB-T)
- Fix for non DVB/ATSC-compliant PMT entries of AC3 audio streams (playback problems of neutrino recordings on Kathrein UFS 913 receivers)
- Selectable stream compatibility between ATSC(USA,Canada,Mexico) and DVB(Europa,Russland,China,Afrika,usw.)
- Fixed problem with PMT less ServusTV recordings (Technisat receivers)
- Installing licensed version on Linux via wine 1.6 rc4 possible (trial version not available and video preview is not working correctly)
- Installing licensed version on MACOSX(Lion) via Crossover 12 possible (trial version not available and video preview is not working correctly)
- Warning info when installing under VMs, that trial is not available
- It could occur, during very short shots (less than 5 minutes), that the first I-frame on a cut could to be skipped
- Unintended lock of the target drive fixed, not allowing to eject (hang out) external drive, as long as the TS-doctor runs
- Additional PID scan at the end of the recording to better detect program switching (ServusTV)
- Detection of program switching is performed now for PAT/PMT less recordings (e.g. TechniSat receivers)
- Improved fix of program switching. Now the timer will be corected automatically if needed (ServusTV)
- Skin-Engine updated
- Default Language_Descriptor for PMT entries without Language_Descriptor
- Error with adding Language_Descriptors fixed
- Improved detection of encrypted areas (ORF HD)
- Read buffer to accelerate the TS File Merger in "TS Paket Mode"
- Option to remove annoying start packets without payload (ORF HD)
- Older AAC formats are now also properly recognized by Remuxer
- Fix: For modified Windows 7 theme (Windows Classic) and 150% system font size the buttons could be not be clicked in the Setup
- Fixed problem when changing the file name in the dialog for saving a new file
- Improved treatment of Sky Select HD recordings
- Fixed virtual cut for multi-file recording
- Improved error handling for AAC audio tracks
- Incorrect PTS DVB subtitles were not fixed when no cut was done
- Support for Estonian language (incomplete)
- French texts in GUI improved (thanks to Phil)
- New version of the Haali splitter 1.13.138.14
- Potential issues after changes of multi screen settings fixed
- Fixed crash on the remuxing of certain footage from Danish HDTV (TV2 HD)
- EArgumentOutOfRangeException (package 0) fixed when creating a new file
- Evaluation and display of parameters of AAC audio tracks
- Optional remuxing from AAC(LATM) to AAC(ADTs) in the Demuxer and Remuxer (can be activated in the settings)
- Remuxer now supports the generation of MKVs with AAC audio tracks about MKVToolnix
Veranderingen voor v1.2.81 - v1.2.82
- Hotfix for burning DVDs using DVD Maker, if there is only one audio track
Veranderingen voor v1.2.78 - v1.2.81
- Problems with cutting of radio recordings fixed
- Fixed loading of the most recently used list of cutting
- Remove blank lines in the Teletext subtitles
- Future updates of the TS-doctor without unnecessary dialogs
- Under certain circumstances, no PCR fix was offered (Viva recordings with TechniSat receivers)
- Create video DVD using Windows DVD Maker (Vista Home Premium/Ultimate, Windows 7 Home Premium/Professional/Ultimate)
- Reload of the recently used cutting list is now controlled via dialog
- If possible, prioritize the AC3 mode for automatic cutting
- Changes for processing of batch lists
- Improved evaluation of the DVB Viewer (ADS) recording time with daylight saving time correction
- If possible, data from additional files (dvr,xml,epg,ADS) are used if there is no Teletext or deactivated Teletext processing
- Patch for incorrectly coded EPG of FOX HD, TNT Serie HD, etc.
Veranderingen voor v1.2.76 - v1.2.78
- For recordings without PCR, the PCR can be rebuilt now
- Support for recordings of regional programmes, where the video codec is changing (H264<>MPEG2)
- Fixed problem with daylight saving time in EPG scan
- Improved automatic cutting
- Improvements in Teletext processing for Eastern European characters
- Support of all common EPG character code tables (ISO6937, ISO8859 1-15)
- Fix for incorrectly specified French and Polish EPG
Veranderingen voor v1.2.71 - v1.2.76
- Fixed Windows 8 menu problem
- Fixed special characters with Hungarian subtitles (SRT-export)
- Support for international character tables for EPG infos
- Improved display and editing of the recording details
- Automatic file splitting maps right the filename now also for single broadcasts
- Fixed a problem with crash of analysis for specific PCR errors
- Support for splitted recordings of DREAMLINK HD receivers
- Missing ". ts"-extension is automatically added when splitting into multiple files
- Fixed problems with the VPS cutting for recordings that have a PCR-wrap
- EPG data take precedence before Teletext program data
- Message and abort is recording has too many missing PCR informations
- Automatic separation of cutting areas to multiple files
- Fix for sporadically not executed "PES length for the video stream to a safe value patching"
- Support for split files of receivers with TitanNit operating system
- Import of the recording details from the EPG file of TitanNit receivers
- Teletext evaluation improves and bescheunigt
- no Teletext evaluation of recording details for ZDF-Kultur and ZDF-Info, as they have not their own Teletext
- Recording details with Teletext evaluation for German Sky channels
- Fixed incorrect detection of the last PCR value for merging of recordings with 192 byte packets (Xoro HRS8500/8520)
- Problems with resynchronizing the TS packet structure in defective recording with 192-byte packet size
- Detection and troubleshooting program switching
- Detect and resolve PCR jumps
- TechniSat recordings can be opened now also via the .rec file
- No more separate handling of recordings with and without cutting
- Fixed a problem with PCR-wraps that resulted in a situation were the PCR wrap sporadically was not removed
Veranderingen voor v1.2.66 - v1.2.71
- Haali splitter is installed only if not already present in the system
- Display of the programmes detected by EPG or Teletext in the timeline
- Teletext was not always parsed at the end of the recording
- Radio recordings can be cutted
- Fixed potential issues in the analysis of the Teletext
- In the timeline panel, the editing cursor will respond in a larger area of the timeline
- The correct cutting images now also be generated when the markers are moved
- Automatic cutting with EPG data (EIT on PID 18)
- In batch mode, the cut list was ignored when the "auto cut" no dialogue has been selected
- Fix for missing REC file for TechniSat recordings, which led to problems for certain recordings
- For the cutting preview the start and end playback time is configurable in the settings
- The selection in the dialog box "Auto cut" the TS-Doctor can be stored
- Fixed a problem with different CharaterSets for Teletext subtitles (ARD page 150,799)
- Cut preview
- Advertising recognition is renamed in "Auto cut", as this is much more accurate
- Automatic automatic cutting is better configurable in the preferences
- If the option "Test/repair startup" is selected in the file merger, the fixed file is created in the destination folder, too
- Removal of incomplete shows at the beginning and end of a recording with automatic cutting
- Quick scan for automatic cutting in VPS mode (much faster)
- Improved accuracy of the automatic cutting in VPS mode
- Fixed problem with missing progress in AR mode
- Problem with not functioning preview solved with TechniSat recordings with malformed packets (Garbage) at the beginning of the file
Veranderingen voor v1.2.61 - v1.2.66
- - Thumbnail window can be docked to the left side of the timeline
- - Info about the used features in the commercial detection dialog
- - Workaround for missing last image of recordings in the timeline
- - In the timeline jumping to the markers is available ( Y and Shift-Y)
- - Fixed a problem with the thumbnail view using the "enhanced video renderer"
- - Teletext missing in the PMT and subtitles can be added now properly (E.g. Neutrino recordings)
- - New tool to manipulate the timer in SRT files (SRT time changer)
- - Commercial detection extended with VPS data
- - The cut in the timeline accelerated by more intelligent handling of the cutting images
- - Improved quality of the cutting images
- - Cutting images now in the correct aspect ratio
- - Improved quality of thumbnail images
- - Thumbnail images now in the correct aspect ratio
- - Aspect ratio for H264 recording (720 x 576 with AR 16/9) corrected in the preview
- - Workaround for flickering in preview if Enhanced Video Renderer is used
- - Improved flow of advertising recognition
- - Fixed problems with the demuxing of radio broadcasts
- - Fixed bug at startup if there were files in the temporary directory and the dialog was closed too late
- - Fix recordings of certain receivers still encountered "file buffer error"
- - Sporadic for splitted recordings with many errors a timer discrepancy was detected incorrectly
- - Showing start PCR and end PCR of the individual parts in the merge log
- - Fix for splitted recordings that contain certain special characters (Unicode) in the file name and as a result, no preview was possible
- - Support for splitted recordings with format "00.000.Recording.ts"
- - Fix for splitted recordings with many encrypted packages at the beginning that resulted in the error message "Sourcefilter could not connect to demuxer" in the preview
- - Different PMTs with same PID are now ignored
- - Encrypted audio streams are automatically removed (Samsung TV)
- - Fix for Newline HD 49 receiver so that the file format is correctly recognized as ALI DVR
- - Display of TS special formats (Enigma, Neutrino, Technisat and DVR) under Stream details
- - When calling via command line (AutoFix) and necessary PCR fix, a temporary file is automatically generates in the temporary directory and deleted afterwards
- - For command line option AUTOCHECK no advertising detection will occur, even if it is enabled in the dialog settings
Veranderingen voor v1.2.57 - v1.2.61
- 1.2.61 - Hotfix for sporadic "File buffer error" during analysis
- - Hotfix for PCR out of range" for Technisat recordings
- - Unnecessary messages about "encrypted areas" removed
- - Skin engine updated
- 1.2.60 - New trial periode
- - Version info in setup window
- - Removed problematic option "Force AC3 consistency"
- - Fixed crash when processing recordings of the Danish channel TCM
- - No unnecessary cutting areas produce, if cutting at the beginning and at the end of an existing section range
- - Now it's possible to cut between the first marker and the current cursor position
- - Clicking on a marker let the cursor jump to the marker point
- - Fix for sporadic problems with the bit rate indicator
- - Fixed crash in the Teletext analysis of Danish TCM
- - Fixed hangs for recordings of Panasonic DMR-BST700
- - Use the recording details of Neutrino XML files, if found
- - Fixed problem with SRT creation for split recordings with cutting areas
Veranderingen voor v1.2.52 - v1.2.57
- - Improved search and execution of program updates
- - Revised GUI for distribution to multiple files
- - The buttons and the timeline are blocked during the creation of the cut point pictures
- - Sporadic problems with remembering the directory for "File open" fixed
- - Automatic append of "_fixed" to the file name can be disabled in the settings
- - Warning if target and source file name are the same
- - Fixed problems with French subtitles
- - Special Danish national characters support via G2 supplementary set
- - Skin engine updated
- - Fixed problems with Danish subtitles from TV1000
- - Encrypted recordings will now stop at an earlier stage to avoid an application hang
- - Removed distinction between subtitle and Teletext via the DataUnitID to work around problems with SIXX Teletext
- - Support for Teletext analysis of SIXX
- - Language finnish added (Thanks to Ropsi)
- - Ansi/Unicode/UTF-8 support for MKVs in TS-Remuxer
Veranderingen voor v1.2.45 - v1.2.52
- Splitting a recording into multiple files, the subtitles are divided accordingly
- Fix for recordings with PCR-wrap where the audio tracks get lost
- Fixed various minor problems with PCR-wraps
- In cutting window the first cutting area will be selected on opening
- Detecting missing/disabled MPEG2 video filters in Windows 8 without Pro Pack
- Window hierarchy revised to allow the application to work in the background
- Adjustments to the batch processing
- Taskbar button now appears correctly in Windows Vista, 7, and 8 on Windows
- Added ThumbnailTooltip for Windows Vista, 7 and 8
- If teletext PTS is corrupted, PCR is used for export of teletext subtitles (Polish HBO and CYFRA +)
- Supporting addition international character sets for teletext (Poland, Estonia, Turkey, Romania, Lithuania)
- Subtitle detection now also via control bit C6 to fixed the sporadic unrecognized subtitles at ARD and ZDF
- SRT export supports UTF8 and Unicode format now
- Memory-Leak in result dialog fixed
- Program update is ignored if a recording file is already opened
- Problem mit deaktiviertem OK-Button im File-Merger gefixt
- Improved concept for subtitle detection at ARD and ZDF
- Revised result dialog
- Display the duration of the deleted advertising breaks in the result dialog
- Potential errors in the "file open" dialog are now caught
- Audio, video and teletext details be sought only in the usable part of the recording
- Drag&Drop of multiple files improved
- Error in Teletext bring mixed up no longer subtitle detection (ZDF page 777)
- Increased number of search points for Teletext subtitles, if the recording is shorter than 60 minutes
- Subtitle lines with "KEINE UT" are now removed
- Number of files in the file merger increased to 1000
- Hotkeys in the timeline for +10sec.[z] und -10sec.[shift z]
- Hotkeys in the timeline for cutting area start[Home] und cutting area end[End]
- In the file merger files that do not consider the package borders, are now better recognized
- Avoiding deadlocks in the Teletext analysis
- Fixed problem with DBox recordings that have set the scrambled flag on all transport stream packets
- Stream processing accelerated
Veranderingen voor v1.2.37 - v1.2.45
- Wildcard support for command line option "AUTODEMUX"
- Search accelerated for Teletext subtitles
- No warning message any longer on files that are larger than 4 GB on exFAT file systems
- No search for Teletext subtitles if the Teletext is disabled in the settings
- Program information from ADS info of the DVB viewer be applied if no program information can be found
- Improved handling of TechniSat recording format (TS4) if the files have been copied directly from the receiver (.ts4, .mks, .rec)
- Incorrect PTS timer for DVB subtitles at RTL are now detected and fixed
- Progress window should no longer force itself into the foreground
- For the AC3 advertising recognition, short AC3 changes are ignored, increased timeout from 1 second to 10 seconds. (ARD,ZDF,etc.)
- Fixed potential issues when opening files caused by file-locking
- Recordings that are fully encrypted, are canceled with appropriate error message
- The new AC3 advertising recognition process the last AC3 change correctly now
- Support for negative timer offsets in SRT export
- AC3 advertising detection completely rebuild to work correctly even with difficult AC3 streams of ARD and ZDF
- Intermittent long wait fixed when creating a new file with recordings of german broadcasters (ARD, ZDF, etc.) solved
- When cutting using PTS is impossible (sporadically for subtitles), then fallback to cut using PCR
- Teletext scan can no longer fail because of VPS data
- Short recordings (smaler then 140 MB) with activated option "Enhanced PCR check" has been sporadically to much cutted
- AC3-advertising detection more resistent against short-time changes within 1000ms (e.g. with ARD, ORF)
- Problem with automatic search for updates fixed
- Improved detection of beginning and end of movies for ARD, ORF using AC3 advertising recognition
- Progress bar for the Teletext analysis
- Teletext analysis can be disabled
- Support for Medion multifile recordings (Rec.ts, Rec.01, Rec.02, ...)
- Fix for recording details overview, where the list contains only one repeating entry
- Possible errors during creation of the DirectShow filter list fixed
- Fix for sporadically missing recording details in recordings of Arte
- Improved formatting of recording details
- Recording details with multiple pages are merged
- Recording details via Teletext for many additional channels (3sat,SWR,N24,MDR,RBB,NDR,EinsPlus,etc.)
Veranderingen voor v1.2.34 - v1.2.37
- Faster application start
- Fixed potential problems at startup
- If the TS-Doctor works in slow idle mode, this is now displayed in the log together with the working speed
- Parsing improved for EDL files to avoid import failed
- Scrolling enabled in error overview
- Multimedia file detection of TechniSat HD-K2/S2 recordings
- Multimedia file detection of TechniSat HD8 recordings
- Accepted now drag and drop multiple files that belong together (splitted files)
- Support for Microsoft DTV/DVD audio decoder removed due to sound problems and unclear license questions
- Settings for separating to multiple files will no longer be lost if the cutting areas are changed
Veranderingen voor v1.2.33 - v1.2.34
- Hotfix for "Resource 1012 not found" error message
Veranderingen voor v1.2.29 - v1.2.33
- Shortcuts in the main window (O=Open, M=Open multiple files, T=Open trimmed, B=Open Batch)
- Shortcuts in the main window (F2=Preserve streams, F3=Prepare patching, F4=Prepare cutting, F5=Only checking, F6=Save new file)
- Fixed a problem with negative values in the dialog for "Open trimmed"
- Problem mit negativen Werten im Dialog für "gekürztes Öffnen" behoben
- Automatic installation of the TS-doctor license file, when it is in the same directory as the installation file
- Wild card in command line mode works again
- When multiple files are processed in wild card processing mode, the entire operation can be canceled by press "Cancel"
- Improved dialogue for separating to multiple files
- Warning before overwriting files in RawCutter
- Remuxer uses the specified output path now
- Detection of Teletext subtitles not marked as subtitles (ZDF page 777)
- Teletext subtitle search speeds up (only 10 areas instead of 18)
- For application priority "IDLE" additional wait cycles are used to reduce the system load by disk I/O
- Improved support for images in the ATSC standard
- Fix for accurate identification of info.dvr from Taiwanese recordings
- Fix for camcorder recordings in MTS format, where "h264 picture parameter buffer overflow" shows up in the log
- The PCR list is canceled if no new PCR value is found within of 1000000 packages
- Creation of the video list of PTS is canceled if no new PTS value is found within of 1000000 packages
- Optional cutting of the recording at the point where the video PTS ends
- Easier installation of LAVFilters
- With DWord registry key "MaxWriteBufferSize" under HKEY_Current_User/.../Settings the size of the write buffer can be reduced to avoid write errors in a VirtualBox VM
Veranderingen voor v1.2.22 - v1.2.29
- Fixed several minor issues with CLI
- Command line parameters are written in the _fixed.log
- Using the language of the Teletext subtitles listed in the PMT
- Fix for cutting recordings from the Smart MX 44 (Sourcefilter could not be connected)
- If automatic search for updates is disabled, the manual search was not working
- Program termination fixed in commandline mode, if extended PCR check finds problems
- Changed auto-closing of the application in the command line mode
- Multi file dialog redesigned and equipped with "Remember answer" checkbox
- SRT subtitles fixed
- Bug report for write errors (out of disk space error) with more detail in the log
- Fixed some French translation mistakes
- Revised closing of the program in batch mode
- Add external SRT subtitle files remuxing MKVs
- Now the editable title from the TS Remuxer is used for SRT subtitles in MKVs
- The attempt to identify stream types will be done in the middle of the file, too
- Detection of additional audio and text streams that aren't listed in the PMT (e.g. switching regional channels)
- Optional insert of the additional audio and text streams in the PMT
- Detection and display of audio and text streams that are not present in the entire recording
- Repeated entries in the PMT are cleaned up now (ORF1/ORF2 via DVB-T)
- For SRT files the time codes now correctly written with a comma instead of a period
- Fixed EDL files generated by the TS doctor (AUTOEDL)
- LAVFilters can be now downloaded and installed via settings / supported tools
- Support for teletext streams without PTS (Sky IT)
- Processing of DVB-Viewer file infos (ADS)
- Transfer of ADS data from source file to new file
- Multi file support for Technisat Skysat S2
- New commandline option "AUTOEDL" creates only a cutting list in EDL format
Veranderingen voor v1.2.16 - v1.2.22
- Improved support of ComSkip
- Number of threads for ComSkip can be modified (donator edition only)
- Easy installation of the donator Edition of ComSkip in the settings
- FileSource in preview revised, should better cope with faulty recordings
- Bad packets are no longer skipped in the preview but replaced by empty packets
- Error in the preview fixed, for the calculation of the maximum file position in recordings with 192 byte packets
- Teletext processing can be disabled
- Fixed sporadic hang while closing the preview window
- Inverting the cutting list fixed (redundant entry was not removed)
- Option to use ComSkip for h264 if a h264-enabled version of ComSkip is installed
- Detection of file extensions of split 4TheRecord recordings
- If ComSkip was called on the menu, the new cutting points were not loaded after the recognition
- Option to to suppress the removal of B-frames at file start for recordings from Das Erste HD, ZDF HD, Arte HD, since some decoders otherwise produce artifacts at the beginning of the file
- WDR HD Teletext subtitles fixed
- Rows with Paritycheck errors in the Teletext subtitles are now ignored
- TS-Remuxer GUI completely revised
- Teletext subtitle support for MKVs
- Default audio stream and default text stream selectable for MKVs
- Track titel for MKVs can be changed
- Language code for the audio and text stream can be changed in TS-Remuxer
- Demuxing of Teletext subtitles into SRT format
- Added a full stop to the file extension for SRT files (movie.[888].srt instead of movie[888].srt)
- TS-Doctor attempts to automatically detect the language of the Teletext subtitles (ger,eng,fre,dut,spa,cze,dan,pol,ita,swe)
- File extension for SRT files now available in the format ".[PageNumber].srt" or ".LanguageCode.srt"
- Time in the Teletext subtitle are fixed correctly now when cutting
- For the DivX H.264 decoder the "fast SampleGrabbing" is now automatically disabled, as it's incompatible with this mode
- If in the commandline the source folder and the destination folder are identically, "_fixed" is added to the file name
- Extraction of teletext subtitles into srt format
- File extension for H264 elementary streams in demuxer changed from .h264 to .264
Veranderingen voor v1.2.5 - v1.2.14
- Correct aspect ratio in MPEG2 recordings is used in the timeline even if "fast Samplegrabbing" is disabled
- Audio quality of the TS-doctor audio messages improved and slightly reduces volume
- Own sounds (.wav) can be used as audio messages
- Intense search for encrypted areas can now be started manually from the menu
- In the Remuxer the audio track are imported in the same order as listet in the PMT (for MKV, TS, m2ts)
- A list with the time stamp of the intersections in the log
- Fixed a sporadic problem in manual "search for updates"
- Optional patch of the recording to fix WindowsMediaPlayer 12 "no audio" problems
- Improved column labels for separate to multiple files dialog
- Potential crashes when parsing broken sequence parameter sets fixed
- Displays a diagnostic code in the DirectX log if TS-Doctor FileSource could not be loaded
- More accurate error message if there are problems loading the recording in the timeline
- Aspect ratio for h264 recording (Danish DR2) with 704 x 576 is now correctly displayed
- The order of the audio streams in the PMT can be changed now
- Fixed problems with enabling and disabling subtitles and teletext
- Better detection of changes of the AC3 mode
- Support for Topfield *.rec/*.001/... multi file recordings
- Precision when inserting silent AC3 frames in the muxer/Remuxer on +-improved 16ms
- Potential problems with lip sync in the Muxer/Remuxer for AC3/EAC3 fixed
- Additional check on encrypted areas
- Encrypted areas can be cutted out automatically
- Commercial detection can be started now manually from the menu (Edit/Detect commercials)
- Automatic commercial detection can be disabled
- Disabled ffdfshow filters are ignored for graph creation
- Calculation of h264 frame order values fixed
- For H264-interlaced recordings the second half frame (P-frame) at the cutting point is taken into account now to avoid flicker
- Cutting window revised
- In the cutting window the selection of the audio track is possible with a new combobox
- Fixed problems in the analysis of pure audio recordings (radio)
- Fixed problems when playing pure audio recordings (radio)
- Broken advertising recognition (AC mode), the cut is closed automatically
- Improved handling of delays for AC3 sound in the muxer/remuxer
- Missing AC3 frames at the beginning are filled with silent frames in the muxer/remuxer
- The sound remains lip-sync now also if errors occure in EAC3 streams for the muxer/remuxer
- The remaining delay is specified in the log for the muxer/remuxer
- The remaining delays are used for the remuxing via TSMuxer or MKVToolnix and should be give synched audio/video
- MouseWheel support for the list of "recognized streams" on the main form
- Fixed a bug in the TS-Doctor Filesource that sporadically resulted in crashes in the cutting window
- Support for LAV Splitter
- Existing .edl cut files are now correctly imported with the necessary adjustment of the cutting points
- In the cutting window the keyboard shortcut "P" can be used for play and pause
- File extensions name.ts, name.ts1, name.ts2 are sorted correctly again
- Multiple files with the extension. ts,. ts1,. ts2, etc. are automatically recognized as splitted file
- Number of frames to be scanned for the first GOP doubled (FOX HD)
- Annoying B-frames are removed correctly now at FOX HD
- Fixed a problem in the calculation of the h264 aspect ratio
- Automatic detection of advertising is the aspect ratio changes (4/3 <> 16/9)
Veranderingen voor v1.1.46 - v1.2.5
- 1.2.5
- Hotfix for splitted files named data0001.ts, data0002.ts, ...
- 1.2.4
- Default value for AC3 scans advertising recognition doubled
- Error message after cancelling the AC3-advertising detection fixed
- Workaround for jumps to the next Iframe, where some Iframes were ignored
- Prevents the overlapping section when start and end on the buttons next to the designation number be changed
- More elegant solution for editing the start and end times of a section range without additional window
- New command line parameter AUTOBATCH automatically starts the internal Batchliste
- New command line parameter: AUTODEMUX
- Added support for the LAVFilters (audio, video)
- ComSkip-advertising detection can be canceled
- File name appears in the header of the cutting window
- Cursor keys left and right can be used now in the cutting form to do frame jumps forward and backward
- Edit of the start and the end times of a cutting area in a separate edit window
- In the selection of the cutting area, just one click with the left mouse button is enough to jump to the beginning or the end of the cutting area
- Design improved in the cutting form
- Some default values adjusted
- Reset button for all settings
- Alternative calculation of video PTS to PCR ratio, if PCR is not on the video stream PID
- Completely offset PCR values are now detected and can be adjusted if wanted (Astra.HD.H264.1080i.Astra.1D.23.5E.10jul.2007.ts)
- Improved sorting of split recordings
- Loading of splitted recordings a part was ignored if file name ended with a Zero (for example: 00000.ts)
- Fixed problem of patching PTS values (delay to PCR)
- Teletext is retained after the cut even if the PTS value of Teletext is outside the tolerance limit
- AC3-advertising detection can be canceled
- Teletext PTS is now automatically fixed for incorrect PTS time base without an error message (ARD HD/ZDF HD - problem)
- Support for the PowerDVD 11 - audio decoder removed, because this filter will no longer allow connection to other filters
- Problematic TS files that were generated with XMediaRecode 3.0.8.0 can now be opened despite "PCR discontinuity > 1000ms"
- Instead of a confusing simple error list, a list of problem areas appears now after the repair
- Support for M2TS export in TS Remuxer
- Packet filters of the cutting engine revised for improved accuracy
- Fixed/minimized artifact problems at cut area for HDTV recordings
- Fixed bug when writing packets in the Packet Editor
- Probleme fixed with IFrame detection for interlaced sources
- Improved creation of the cut images when using CoreAVC- or Mainconcept h264 filter
- Fixed bug when cutting between markers, was introduced in the last version
- Cut keys are now updated when the markers are visually moved
- Cut across several cut areas
- Joining together across several cut areas
- Adjusted entries for the timeline popup menu in the cutting form
- Fixed problems opening of m2ts (192) files
- Support for the CyberLink demuxer removed, because it's incompatible to the I-Frame detection filter
- In the cutting form the key "x" can be used now to set a marker
- In the cutting form the key "Del" can be used now to delete the area between the markers
- In the cutting form the key "Ins" can be used now to add/join the area between the markers
- In the cutting form the button "i" can be used to jump one I-Frame forward and shift & "i" to jump backward
- In the cutting form the button "f" can be used to jump one frame forward and shift & "f" to jump backward
- In the cutting form the button "s" can be used to jump one second forward and shift & "s" to jump backward
- In the cutting form the button "m" can be used to jump one minute forward and shift & "m" to jump backward
- Possibility to use a marker to divide an area into two areas
- Markers are now rounded to the frame interval time
- Check added for "PCR discontinuity" in log
- Improved detection of first I-Frame in MPEG2
- I-Frame detection for MPEG2 with CyberLink PowerDVD 11 filters now working
- I-Frame navigation completed
- I-Frame detection for BBC HD fixed (slice_type > 4)
- Correct cut now also possible for BBC HD - recording
- Fallback function if the first I-Frame isn't found
- Acceptable delay between video and other streams increased to 10 seconds
- Corrected reading of value for "CROP =" in the commandline
- AAC audio stream from BBC HD is recognized correctly as AAC track if there is no PMT
- Fix for sporadically problem where after cutting the stream duration was 00:00:00.000
- Commercial detection is more accurately regarding the positions of cutting
- MP4 output for TS-Remuxer (H264,MPEG-Audio,AC3)
- Correct display of PTS timers in the log above 23:59:59.999
- Significantly improved cutting accuracy in MPEG2 and h264
- Fixed a bug when closing the thumbnail view
- New commandline option LOG writes a short log of the processed files
- Check for the destination filename in the batch list, so no destination file name can be used that already exists in the list
- Revised section distribution to multiple files, file names can be changed
- Display of the aspect ratio (16:9 or 4:3)
- Fixed a sporadic error in the garbage-scan
- Search for the last usable TS packet in the stream improved
- When a cutting point is set the image no longer jumping around some frames when using certain video filters
- Not ISO639/2 compliant language codes are no longer ignored and can be overridden
- If there is no language code for an AC3 stream, the language information can now be added to the PMT
- Improved Graphbuilding process
- Improved compatibility to MainConcept and CyberLink h264 filters
- Precaution against possible hang (deadlock) when releasing the decoder filters after previewing
- I-Frame display in the preview window for Mpeg2 and H264 recordings
- Problems with Microsoft DTV-DVD Video Decoder fixed
- In the cutting form a jump to the next I-frame is supported
- Additional warning text when deleting the complete batch list and a icon was placed on the button
- Correction of the frame rate in the preview window when the muxer returns an incorrect value
- Batch processing now shows "Finished" on the progress bar when the processing is done
- Detecting a still encrypted stream start and ability to cut the encrypted area
- Support of the Lithuanian language (thanks to Andrius)
- Fix for incorrect Teletext error messages on some recordings [PESLENGTH]
- Error detection of Polish teletext page number
- New trial period for version showing "trial period expired"
- Sporadic frame type detection problem fixed
- Start of the TS-Doctor trial version with FreeCommander no longer makes it necessary to reinstall the TS-Doctor
- Read TS packages optimized (10-15% faster)
- Fixed bug in directory selection in the TS demux
- Progress bar when the recording format of Minerva repairing TV sets
- In the timeline problem fixed that could cause that jumping with "jump backwards" leads to a jump prior the zero point
- Teletext_Descriptor is now correctly evaluated and properly display the language for the Teletext
- Teletext_Descriptor is evaluated in the log
- Patching the Teletext pages in the PMT is possible now (858-> 888 subtitles)
- Mpeg1 audio streams with 320KBit of radio recordings are now properly detected and also the demuxing works with this streams now
- Extended progress bar when opened in TS demuxer
- In the mode "Only checking" now always the correct source file is played
- In the mode "Only checking" now all cutting and patch procedures are skipped
- Missing LanguageDescriptor will be inserted if needed
- Tools menu reorganized
- Disk tool to determine the real read and write speed of storage media
- [Alt]+[Enter] for switching between fullscreen and normal fixed
- Failure during reinstall of TSMuxers fixed
- Adjusting the frame rate for interlaced(PBAFF) H264 recordings with MKVToolnix
- Warning if file already exists in TS Remuxer
- Error preview without "Fast sample grabbing"
Veranderingen voor v1.1.35 - v1.1.46
- Screenshots with fast sample-grabbing fixed
- TS-Doctor Filesource integrated into the application
- Registration of TS-doctor Filesource-filter no longer necessary (should fix some installation problems with restricted user rights)
- Fixed memory leaks
- Improved behavior of the progress window
- No individual entries for deleted AC3 packages in the log, but a summary at the end
- Improves accuracy of single frame view (ffdshow, CoreAVC, Mainconcept, Cyberlink)
- Workaround for inaccurate seeking with ffdshow by using "fast Samplegrabbing" (can be activated under settings/preview)
- In line with wild card, "AUTOFIX" is now the default function (for example: tsdoctor.exe C:\tmp\*.ts C\fertig\)
- Fix for: "fast Samplegrabbing" can't be activated
- New command line parameter for RawCutting at the beginning and end of a file "CROP=XX" where XX is the size in MByte (for example: tsdoctor.exe C:\tmp\*.ts CROP=10 C:\fixed\)
- Message that VMs is not supported in the trial version will now produce a button to register a license file
- Batch processing of problematic recordins with preliminary cut
- More simple Muxer selection in the Remuxer
- Cursor now changes in the timeline according to the function
- For enabled quick Samplegrabbing in MPEG recordings the aspect ratio displays correctly again in the cutting window
- TS format converter now sets the output file name automatically
- Doubled the number of buffered frames in thumbnail view
- Possible errors when closing the editing window are better caught
- I0006 error fixed for Windows 7 systems with multiple users
- Opening of problematic recordings with raw cut at the beginning and at the end
- Annoying timer locking function removed
- Now marked areas can be added in the timeline, too
- Update of the cutting images improved after the cut
- Editing in the editing forma has a better response time
- Problems with blocked preview if the file and the old cutting list is loaded again
- The newly open files with PCR reset bug fixed
- Extended PCR check adjustable
- Groupboxes more clearly structured in preferences
- Eliminates accidental start of playback when maximizing/normalization of the cutting window
- Fixed problems with the buttons in the resizing of the editing window
- When you close the cutting window the window position and size is only stored if window is not maximized
- Fixed a bug in the PCR index list
- Fixed problems when shooting with padding data
- Detecting and repairing of recordings with PCR reset (Unitymedia cable)
- Fix for the AC3 advertising detection
- Support for new Gabest MPEG splitter to fix playback of TV1000HD
- Details on the occurrence of AC3 channel changes
- AC3 advertising detection works well for recordings with PCR wrap, now
- For the AC3 advertising detection the recognized channel-count of the main movie is taken into account now
- The TS format converter now remembers the last set format
- Correction of the stream ID handling is now selectable under "Diaglog settings"
Veranderingen voor v1.1.29 - v1.1.35
- Import of Ali format type 1 (Xoro HRT 5000)
- Separate treatment of Ali format type 1 to 3 when opening
- Intelligent detection of file overlapping for Ali format type 1
- Log entry for filechange on Ali formatted files
- Support for Mainconcept demuxer if "fast sample grabbing" is deactivated
- Discontinuety error now with concrete time
- For recordings without PMT and with two video tracks (Triax receiver) the video track with the highest stream share is prioritized
- Buffer for MPEG2 video stream increases to avoid problems with HDTV in MPEG2
- Display problem in the progress window of the *.sc and *.ap index creation fixed
- Link to support forum added
- Problems with deactivated border decoration fixed
- If no video track in preview then no frame grabbing
- Language modul and translations improved
- Problems with Enimga *.sc and *.ap index creation fixed
- Enimga index creation can be permanently activated in Settings/Correction Behavior
Veranderingen voor v1.1.14 - v1.1.29
- Thumbnail view for the cutting preview
- Single image view with buffered images in reduced quality
- Fast cutting screenshots can be activated under Settings/Preview "Use fast sample grabbing methode"
- Volume in error preview is now correctly set
- If no supported video decoders are found, the "fast frame grabbing" is disabled by default
- If "fast frame grabbing" deactivated, "Microsoft DTV/DVD Video Decoder" ist supported under Windows Vista/7
- Fix for error when using the "classic Windows theme" under Win7 and "special window border" is disabled
- Update of the progress bar at the demuxing/remuxing fixed
- The file merger will no longer be confuse by PCR values on PID $1FFF
- Detection of split recordings of Xoro HRS 8520 and Xoro HRS 8600
- Detection of timer problems during the opening of split recordings
- Fix for MPEG audio streams in MKVToolnix remuxer
- LanguageDescriptor for MKVs with MKVToolnix is now taken from the TS file
- Tooltip animation is switched off now if option "Disable Windows animation" is active
- Support of Drag&Drop for splitted files
- Description of the audio tracks in the timeline improved, PID now hexadecimal
- Better support for systems with multiple user accounts
- Check for sufficient disk space for the remuxing
- Note and abort when the first PCR value cannot be found
- Search depth first PCR and first PTS value doubled
- Message in the Remuxer if no muxers (tsMuxer or MKVToolnix) is installed
- info.dvr recognition problem by Eastern European channels fixed
- tsMuxeR control fixed, which caused that tsMuxeR hangs when converting to BluRay, AVCHD
- Automatic creation of Dreambox (Enigma) .ap and .sc files (for make forward and rewind work on the boxes)
- Manual creation of the index of the Dreambox (Enigma) .ap and .sc Dateien via Tools/TS Index Creator
- Detection and elimination of AC3 gaps in TS-Demuxer
- Detection and elimination of straying video frames in TS-Demuxer
- Code for Language_Descriptor improved for missing PMT
- TS-Remuxer with lip sync fix for AC3 streams with errors and gaps
- MKVToolnix download under "Supported Tools"
- MKVToolnix can be used as muxer in TS-Remuxer
- Header compression disabled by default when MKVToolnix (WDTV compatible)
- If you open the preview a warning is displayed now, if not directly supported video filters are found
- Fixed problems with the beginning of the Stream, sporadically led to missing sound in certain media players or video tools
- Credits for used libraries
- Improved language support
- French language support (thanks to Phil)
- French manual (again thanks to Phil)
- Problem in RawCutter for file splitting fixed
- Now the output path is observed in commandline AutoCheck
- Wildcard support for commandline (for example: tsdoctor.exe C:\tmp\*.ts AUTOFIX C:\finish\)
- ComSkip is not called in batch mode again
- Fixed problems after deleting an entry of the cutting list
- Delete entry added in the cutting Preview popup menu
- Added popup menu for the most important functions in the timeline
- Removing of the cut list is now setting the cut list completely to the initial state
- TSDoctorFileSource is now allways used as a filesource
- Garbest splitter is no longer supported because the combination of TSDoctorFileSource and Haali splitter is better
- Filters are now previously checked whether the necessary file is available
- DirectShow filter info revised
- Registering and unregistering of DirectShow filters
- Remove from filter registrations also for filters that no longer exists (administrator privileges required)
- Automatic mode for the playback filter (TS-doctor selects the best filter that is found in the system)
- Sampling quality of 720p footage in thumbnail view doubled
- Frame style of the single frame view adapted to the style of the thumbnail view
- Fixed hangs when cut on preview when editing cursor was on the right
- Support for PowerDVD 11 playback filter
- Support for Elecard AVC playback filter
- No longer supports Microsoft-DTV filter due to incompatibilities regarding new features and common playback problems
- Auto-registration of compatible filters (Magix Video deluxe 17, Cyberlink PowerDVD 11)
- Revised display of compatible DirectShow filter
- While opening a file the menu is disabled
- Automatic detection of TRP-multimedia file recordings (Vantage, Technomate, etc.) and opening of all associated files
- Wait during position change removed to have faster jumping again
- Display of the update status during frame grabbing
- Permanent grabbing during playback disabled
- Cutting screenshot no longer hangs if the sectional view can not be created
- Short audio noise fixed after construction of the graph in the cutting preview
Veranderingen voor v1.1.7 - v1.1.14
- Revised log formatting
- Graphical representation of the playback graph
- Support for ComSkip (Mpeg commercials detection)
- GUI routinen updated
- H264 cut revised. Should deliver now much more accurate results without artifacts at the cutting areas
- Errors and warnings are displayed in the progress window as lines
- Batch checkbox disabled when divided among several output files
- Cut regions can now be distributed to different files.
- Number of menu entries for "Last open" can be set.
- Number of menu entries for "Last created" can be set.
Veranderingen voor v1.1.6 - v1.1.7
- Fixed refresh of the display of the playing time after the cut
- Tasklist progress bar in Windows 7
- Improved alignment of the text of the Streaminfos
- Warnings and errors were swapped in the stream overview
- Discontinuety warnings are now associated with the individual streams
- Button to save the DirectX log to disk
Veranderingen voor v1.0.89 - v1.1.6
- Compiler update
- Unicode for better language support
- GUI design changed
- Better support for Windows 7
- Application and setup are digital signed now with Microsoft Authenticode
- Support of ISO639 language descriptors for audio and text streams
- Enhanced video bitrate chart
- Enhanced result dialog after repair/cut
- Progress bar integrated into main form
- Display of stream details after analysis
- Source and destination folders for FileMerger will now be stored
- Easier batch processing
- Haali Video Renderer no longer supportet because of big problems with Windows 7
- New Haali Media Splitter from 03/03/2011
- During program start ffdshow filters will be checked for being active
- If Mpeg splitter setting on default and TS-Doctor Filesource active, Haali Muxer is forced, if available
- History for last opened files
- History for last created files
- Delete button for batch list
- Warnings and hint for crypted (scrambled) PES packets
- Better message for PMT problems
- Video bit rate will be displayed with average value now
- Video bit rate calculation speedup
- Use in multi user environment should be possible now
- Extended protection against modification of the installation files
- Fixed bug in the Setup partially prevented the installation of updates
- Individual batch entries can be deleted
- Fixed incorrect disk space warning on network drives (UNC)
- When you cancel due to limited space on the destination disk, the loaded recording is maintained
- Additional rewind buttons for 1 minute in the timeline
- Sizes of the stream components are now displayed in the log
- !!! UPDATE FROM 1.0 TO 1.1 IS FREE OF CHARGE !!!
Veranderingen voor v1.0.67 - v1.0.89
- Support for Cyberlink PowerDVD 10 H264 filter and demuxer
- Emulation prevention buffer size enlarged
- Fixed large number of warnings after "Check only", although no corresponding entries in the log
- Problem with info3.dvr files fixed introduced in Beta 1.0.84
- Saving of last used path can be deactivates under preferences now
- Fixed sporadic error while creating a new PAT for PAT-less recordings
- PAT was not rebuilt if old PAT was corrupted (BBC radio)
- Problems solved if a faulty TS package is located directly in front of the PMT
- Support for the DVICO PVR format (*.tp)
- Fix: Enhanced stream type detection of PMT less recordings (Living HD)
- Problem solved for Czech DVR recordings, where no PIDs are found
- List of file names for multi file recordings (splitted file) in log
- Stream type detection for files that have no PMT are no longer scanned at the beginning of the file to not get "PMT not valid" for files with "bad" beginning
- The last used path for saving is now correctly set
Veranderingen voor v1.0.58 - v1.0.67
- Automatic detection of commercial breaks and creation of a cutting list (for AC3 2.0 <> 5.1)
- If in fullscreen mode the end of the stream is reached the video mode will be switched back
- Preview also for PAT/PMT less files
- Button animation in cutting window deactivated
- Reopening of info.dvr and info3.dvr
- Timing problems fixed, where fast repeated pressing on the foreward or backward button leads to an exception
- Fix: Cutting point where not be prepared correctly if a file was reopened
- Nicer ES bitrate display
- Potentially buffer overflow bug in H264 parser fixed
- Support for info3.dvr recordings from Comag receivers and clones
- Complete read buffer procedures revised and enlarged, because of this it should runs faster for Multi Core systems
- Opening and cutting of multi part recordings without previous merging (for the beginning only for comag recordings [info.dvr,info3.dvr])
- Fullscreen mode for the preview in the cutting window (under Popup menu or Alt+Enter)
- Error in FileMerger window fixed, where the destination filename could not be entered manually
- A warning in the FileMerger was launched if the destination file was larger than 4 GB. From now on this will happen only for non NTFS filesystems
- Bug in DirectShow code fixed, that prevents the stream from further processing after opening the cutting window
- DirectShow code replaced in many places, improved and made more stable
- If stream can not be rendered, the TS-Dcotor tries out alternative filters
- New own DirectShow filter (TSDoctorsource.ax) that can filter out invalid or wrong packets for the preview (TRP files and other should be playable/cuttable without previous repair)
- The TS-Doctor DirectShow filter can be activated over Settings/Preview "Use TS-Doctor Filesource"
- Many Code optimizations
- Bug in Mpeg2 video parser fixed
- Long pathes are not displayed fully in file merger, now the window can sized and the full destination filename as hint
- Bug during finding of "garbage data" at the end of a stream fixed, that sometimes caused a infinite loop
- Bug during resynchronization of M2TS files fixed
- Access violation fixed, that happend because of incomplete H264 frames at the end of PES packets
- Buttons in cutting window staying active during playback
- If during playback in the timeline, the cursor is moved then after releasing the mouse the playback continues
- Check for updates now in a separate thread so that the start of TS-Doctor will not hang in the absence of internet connection
- Log window will no longer be updated constantly, thus faster processing
- Start of the TS-Doctor accelerated by placing the detection of the directx version into a separate thread
- Analysis of streams accelerated
- Menu entry for the RawCutter remained disabled after editing a stream
- Quick selection of stream parts created for the RawCutter
- Improved handling of the timeline, drawing no longer depends on the y-axis
- When changing a cutting area, this area is highlighted
Veranderingen voor v1.0.45 - v1.0.58
- Loading the filters for the preview improved and made more reliable
- Support for "Microsoft DVT-DVD Video Decoder (Mpeg2/H264)" (included in Windows 7)
- Support for "Microsoft DVT-DVD Audio Decoder" (included in Windows 7)
- Possible sporadic error in the preview window fixed that prevent the playback on some Window7/x64 systems
- Sporadic "range error" in preview window fixed
- Support of newer NAL_unit_types for H264
- Support of H264 video profile "Stereo High" (3D-Movies)
- Errors in the calculation of the audio / video delays fixed
- Patch to detect DirectX 11 (bug in DirectX 11 DXDiag API)
- Deactivated ffdshow filter are now detected automatically and over a dialog it can be activated
- DirectX log extended by a few points
- Option "Treat no PIDs as reserved" does allow it to process non DVB/ATSC compliant ts streams (e.g. Nova (Cable TV))
- Automatic patching of non-compliant pids
- Problems with Italian time format fixed
- New time edits in cutting window
- For the new time edits copy/paste works now (format is hour,minut,second,milli second [HH:MM:SS.MMM] and the separators are ignored)
- Setup can now be continued without administrator rights if you have a license file and you don't need the 30 days trial period
- Setup without trial period can be forced by parameter "NoTrial" e.g. "TSDoctor_eng.exe/notrial"
- Auto screenshot setting will now be considered for opening the cutting window
Veranderingen voor v1.0.28 - v1.0.45
- Files in the temp folder will now be deleted only after inquiry
- This version no longer appears as a beta version
Veranderingen voor v1.0.25 - v1.0.28
- Problem solved with dialog "Trial time is over" even the 30 days are not over yet
- Possibility to install the license file in the "Trial time is over" dialog
Veranderingen voor v1.0.23 Beta - v1.0.25
- Hotfix for crash with activated H264 option "Remove filler data"
- No longer for videotext streams that will be deleted
- Output folder for MKV export was not used
Veranderingen voor v1.0.22 Beta - v1.0.23 Beta
- Registration of license files with help of a menu entry
- In the cutting window a double click on a cutting area leads to a jump to the beginning of the cutting area
- During graphically adding of a cutting area the video cursor will follow the selected area
Veranderingen voor v1.0.20 Beta - v1.0.22 Beta
- Cutting window redone and cutting list added
Veranderingen voor v1.0.19 Beta - v1.0.20 Beta
- Workaround for "Trial expired" problem with optional Trial license file
- Displaying date on "Trial expired"
- Main window and cutting window are storing last position and size
Veranderingen voor v1.0.18 Beta - v1.0.19 Beta
- Enhanced DVR export
- Different small changes
Veranderingen voor v1.0.13 Beta - v1.0.14 Beta
- Error in H264 parser fixed, which could caused aborts especially with camcorder recordings
- Potential probleme while setting cutting marks fixed
- Double click on start or end mark will set the preview to that point
- Lock funktion for start and end marks. When lock is active than you can use -10,-1,+1,+10 buttons to move marks
- In cutting window you can insert a cutting area by pressing the left mouse button and move at any part of the timeline
- Delete of cutting areas
- Some errors in the timeline were fixed
- Additional PID scan in the middle of the file (to fix rare videotext detection problems)
Veranderingen voor v1.0.10 Beta - v1.0.13 Beta
- Hotfix for files with more than 2 cutting areas
Veranderingen voor v1.0.8 Beta - v1.0.10 Beta
- Error message during program start fixed, no longer an empty window
- Some translation errors fixed
- Hotfix for the cutting (Duration: 00:00:00.000)
Veranderingen voor v1.0.6 Beta - v1.0.8 Beta
- Analysis of the slice headers for H264 video streams (I-Slice/P-Slice/B-Slice)
- Sporadic hangs during PID/PAD/PMT scan fixed
- Better finding of a valid stream start
- Handling of Comag files improved
- Problems with missing parts in file merger fixed (Division/zero problem)
- Search for updates integrated into the menu
- Free beta test phase extended till 2/28/2010
Veranderingen voor v1.0.5 Beta - v1.0.6 Beta
- PMT and PAT parsing complete redone
- Support for PointerFields in PATs and PMTs
- Support of big PATs (more than one packet)
- Display in the main form if PAT or PMT has to be created new
- Faster read/write procedures
- Two modi "Check" and "Fix"
- For PCR tolerance check the correction facility removed, because of too many problems caused by this
- Warning for overwriting of files